Closed-Cathode Air-Cooled Fuel Cell Power for AIR, EDGE, FIELD

AIR / UAV & HIGH-ALTITUDE FLIGHT

Engineered for

thinner air.

Lightweight, closed-cathode air-cooled fuel-cell power for UAVs and high-altitude platforms at 3,000–6,000 meters. Maintain performance in cold, low-air-density environments without an external humidifier.

Available output depends on environmental conditions and system configuration. Request model-specific data.

HYCUS X SERIES

FLIGHT POWER

Powerpack or OEM stack integration

Powerpack or OEM stack integration

3,000–6,000 m

High-altitude application range

−35°C operation

X series · specified conditions

1.25–3.5 kW

X-series rated powerpack output

CHOOSE YOUR INTEGRATION LEVEL

From stack to flight powerpack.

X-series powerpacks support UAV power integration. N-series stacks give OEMs a building block for their own system architecture.

Model

Rated output

Product mass

Integration focus

1.25 kW

3.1 kg

Lightweight fuel-cell powerpack

1.6 kW

3.4 kg

Lightweight fuel-cell powerpack

2.5 kW

5.7 kg

Lightweight fuel-cell powerpack

3.5 kW

6.3 kg

Lightweight fuel-cell powerpack

1.4 kW

1.17 kg

OEM stack integration

2.0 kW

1.4 kg

OEM stack integration

4.0 kW

2.6 kg

OEM stack integration

Catalogue ratings. Mass excludes external hydrogen storage and other integration equipment. N-series values describe stacks; X-series values describe powerpacks.

DURABILITY & ENVIRONMENT

Understand the operating envelope.

Long-duration performance

TerraLIX reports performance retention beyond 3,000 hours under defined test conditions. Request the applicable model, load profile and retention data.

Cold operation

X-series catalogue range: −35°C to +35°C for operation; −20°C to +35°C for start-up.

High-altitude integration

Maximum catalogue altitude is 6,000 m. Confirm the combined altitude, temperature and load envelope for your aircraft.

Endurance results and warranty terms are distinct. Request the applicable warranty and test conditions; performance is not guaranteed to remain unchanged at every altitude.

BEFORE YOU INTEGRATE

Technical questions, clear next steps.

LET’S DEFINE YOUR POWER REQUIREMENTS

Bring us your next challenge.

Tell us what you are building. We’ll help you explore the appropriate product, operating conditions and integration scope.

support@terralix.com

Prefer to start with the specifications?

Open the HYCUS catalogue · PDF

August 2026 edition. DION 12 is not included.

Opens an email draft in your email application. Nothing is sent or stored by this page. Review the draft and send it when ready.

Closed-Cathode Technology. Application-focused power.